OEM Pressure Transducer Featuring Exceptional Proof Pressure and Stability Specifications- Vacuum to 6000 PSI (400 Bar)
Quick Specs...
-
Voltage and Current Output Models
-
Gauge, Vacuum, and Compound Pressure Models
-
General Purpose and Wash Down Enclosures
-
High Proof Pressure Achieved by Thicker Diaphragm Construction
|
|
|
Overview / Design Principle:
The 1200 series pressure transducer features stability and toughness via its CVD and ASIC design coupled with a thicker diaphragm. The thicker diaphragm enables these sensors to survive most pressure spikes caused by pump ripple, solenoid valves, etc. A modular design allows special ordering of fittings, electrical cables, etc. for OEM applications. The ASIC and CVD technology enables Gems to offer almost any output over any pressure range.
Applications:
-
Off Highway Vehicles
-
Natural Gas Equipment
-
Semiconductor Processing
-
Power Plants
-
Refrigeration
-
Robotics
-
HVAC
|
|
|
Specifications
|
Input
|
Pressure Range
|
Vacuum to 400 bar (6000 psi) Gauge datum only
|
Proof Pressure
|
4 x Full Scale (FS) (<1% FS Zero Shift)
|
Burst Pressure
|
>35 x FS <= 4 bar (60 psi);
>20 x FS <=40 bar (600 psi);
>5 x FS <=400 bar (6000 psi)
|
Fatigue Life
|
Designed for more than 100 million FS cycles
|
Performance
|
Supply Voltage Sensitivity
|
0.01% FS/Volt
|
Long Term Drift
|
0.2% FS/year (non-cumulative)
|
Accuracy
|
0.5 % FS typical (optional 0.15% FS)
|
Thermal Error
|
2.0% FS typical
|
Compensated Temperatures
|
-20°C to 80°C (-5°F to 180°F)
|
Operating Temperatures
|
-40°C to 125°C (-22°F to 260°F) for elec. codes A, B
-20° to 80°C (-5° to 180°F) for elec. codes 2, D
-20° to 50 °C (-5° to 125°F) for elec. code F temperatures > 100°C supply is limited to 24 Vdc.
|
Zero Tolerance
|
1% of span
|
Span Tolerance
|
1% of span
|
Response Time
|
0.5 ms
|
Mechanical Configuration
|
Pressure Port
|
See ordering chart
|
Wetted Parts
|
17-4 PH Stainless Steel
|
Electrical Connection
|
See ordering chart
|
Enclosure
|
316 SS, 17-4 PH ss
IP65 for elec. codes A, B, D, 2
IP67 for elec. codes F
IP30 for elec. code "3" with flying leads
|
Vibration
|
70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 200 Hz @ =20g Peak per MIL-STD.-810E Method 514.4)
|
Acceleration
|
100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logarithmically to 0.0007% FS/g for 400 bar (6000 psi) range
|
Shock
|
20g, 11 ms, per MIL-STD.-810E
Method 516.4 Procedure l
|
Approvals
|
CE, UR (12 ET, 16 ET Intrinsically safe)
|
Weight
|
Approx. 100 grams (additional; cable 75 g/m)
|
Voltage Output Units
|
Output
|
See ordering chart
|
Supply Voltage (Vs)
|
1.5 Vdc above span to 35 Vdc
|
Min. Load Resistance
|
(FS output / 2) K ohms
|
Current Output Units
|
Output
|
4-20 mA (2 wire)
|
Supply Voltage (Vs)
|
24 Vdc, (7-35 Vdc) Above 100°C supply limited to 24 Vdc
|
Max. Load Resistance
|
(Vs-7) x 50 ohms
|
|
|
|